Display
Month
Heart rate symbol
Memory record
Low battery indicator
Date Hour
qo-äH
Iva88
Fig. 9
Minute
Measuring
error display
Storing measurement data
After each blood pressure measurement, the systolic pressure, diastolic
pressure, pulse rate and the time & date of specific day will be automati
cally stored. Memory is always the most recent one. Once the memory
is full, the oldest values will be overwritten.
Recalling stored readings
• Press "Memory" (3) button, M:OO will appear on the display if there is no
data stored in the memory. If there is data stored in the memory, the latest
recorded set of measurement which is the systolic pressure, diastolic
pressure, pulse rate, and the recording time and date and M:OI will appear
on the display for 1 minute.
• press the "Memory" (3) button again to read the next line of stored data.
The data called up on the display with 2-digit memory number (ex. M:02).
•Press the "Start/Stop" (2) button to exit the memory mode.
Erasing data
• press the "Memory" (3) button into memory mode.
• Press and hold the "Mode" (5) button and then press the "Set" (4) button,
all the stored data will be erased and CLR will show on screen.
• To check if the data was erased, press the "Memory" (3) button, no data
should show up on screen, but date, time and M:OO.
Low battery indicator
When the low battery indicator flashes on the display, it means
the battery is low and the four batteries need to be replaced with alkaline
LR6 (AA) batteries.
Calibration
This product has been calibrated at the time of manufacture.
If used according to the use instructions, periodic recalibration
is not required. If at any time, you question the measuring
accuracy, p ease contact an authorized Service Centre (see
package insert for a local Service Centre).
oos
woo
CLR
Setting month, date and time
a. Press C' (5) button ("month" starts flashing)
Press (4) button to set the correct month (1,2,3,.....12)
b. press (5) button again ("date" starts flashing)
Press (4) button to set the correct date (1
c. Press (b (5) button again ("hour" starts flashing)
Press @ A (4) button to set the correct hour
d. Press C) (5) button again ("minute" starts flashing)
Press (4) button to set the correct minute (0,1
e. Press button again to lock in time settings. Digits will stop flashing.
Taking a measurement
1. Wrap the cuff around the arm (see "Applying the arm cuff" section).
2. Sit upright on the chair to have a correct posture.
3. Press the (2) button. All elements of the display indicate
'888' during the first 3 seconds. (Hg. 9) The measuring blood
pressure symbol will then flash on the display and the air
pressure will automatically pump up to certain pressure
level and start measurement. Do not move or talk in the midst
oftaking blood pressure measurement.
4.After the air pressure has increased, it will slowly decrease
When the pulse is detected, the HEART RATE symbol will
start flashing. After taking blood pressure measurement, the
product will turn off automatically after 1 minute.
Memory function
Your blood pressure monitor can store the latest readings of 32 measurements.
6
Manufacturing date is given by the LOT number on the back of the product. The three numbers
after LOT represents the day of the year of manufacture. The two last digits of the year of
manufacture. An example: LOT 2501 OKYD — this product has been manufactured on the 250th
day of the year 2010.
Storage and cleaning
• Always keep the unit in the carrying case after its use.
• Do not put the item directly under the sunlight, in high temperature or humid and dusty
places.
• Do not store in extremely low (less than -200C) or high (more than 600C) temperature.
• Use a piece of cloth with water or mild cleansing agent to clean the case and then use a piece
of dry cloth to wipe it dry. Use a piece of dry cloth to wipe the cuff when it is dirty.
• Do not use any strong cleansers to clean it.
• When the unit is not to be used for a long time, remove the batteries. (Batteries may leak or
cause harm).