Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 1. sayfa 1 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 2. sayfa 2 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 3. sayfa 3 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 4. sayfa 4 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 5. sayfa 5 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 6. sayfa 6 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 7. sayfa 7 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 8. sayfa 8 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 9. sayfa 9 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 10. sayfa 10 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 11. sayfa 11 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 12. sayfa 12 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 13. sayfa 13 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 14. sayfa 14 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 15. sayfa 15 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 16. sayfa 16 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 17. sayfa 17 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 18. sayfa 18 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 19. sayfa 19 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 20. sayfa 20 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 21. sayfa 21 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 22. sayfa 22 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 23. sayfa 23 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 24. sayfa 24 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 25. sayfa 25 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 26. sayfa 26 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 27. sayfa 27 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 28. sayfa 28 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 29. sayfa 29 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 30. sayfa 30 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 31. sayfa 31 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 32. sayfa 32 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 33. sayfa 33 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 34. sayfa 34 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 35. sayfa 35 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 36. sayfa 36 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 37. sayfa 37 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 38. sayfa 38 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 39. sayfa 39 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 40. sayfa 40 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 41. sayfa 41 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 42. sayfa 42 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 43. sayfa 43 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 44. sayfa 44 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 45. sayfa 45 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 46. sayfa 46 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 47. sayfa 47 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 48. sayfa 48 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 49. sayfa 49 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 50. sayfa 50 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 51. sayfa 51 Actaris Doğalgaz Sayacı G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) 52. sayfa 52


Actaris G 25 SERİE 0 DÖNER PİSTONLU (ROTARY) Doğalgaz Sayacı

-  Le compteur doit etre installe sans contraintes sur la canalisation. Les brides doivent etre
   alignees correctement. Le couple de serrage des boulons ne doit pas exceder 100Nm pour M16, 
   150Nm pour M20. Veuillez serrer les boulons par paires opposees.
-  Un accouplement souple peut etre utilise pour assurer une installation sans contraintes.
-  L'utilisation d'un filtre place en amont du compteur est conseillee pour des gaz qui presentent un
   contenu particulaire eleve. Voir § 3.2
Avant l"installation :
-  S'assurer que la canalisation en amont du compteur est exempte de poussieres.
-  Enlever les obturateurs places dans les orifices d'entree et de sortie.
-  S'assurer que le sens d"ecoulement du gaz correspond â la fleche situee sur le compteur.
-  S'assurer que les pistons tournent librement.
3.2 Filtration 
Les compteurs â pistons rotatifs fonctionnent mieux si le gaz ne contient pas de particules. Par 
consequent, il est conseille de filtrer le gaz en amont du compteur. Le niveau de filtration 
recommande est d'au moins 100 Nm. Lorsque le compteur est en service, il faut verifier 
periodiquement la proprete du filtre, notamment dans le cas d'une nouvelle installation ou apres 
l'execution de travaux sur la tuyauterie en amont du compteur.

3.3 Lubrification 
3.3.1 Generalites
Choisir le lubrifiant en fonction des conditions d'exploitation. Le lubrifiant doit etre neutre et non 
detergent. Important :
-  Une lubrification insuffisante peut causer une usure prematuree du compteur.
-  Une lubrification excessive peut egalement entraîner des problemes. Un surplus de lubrifiant
   peut contaminer la chambre de mesure, deteriorer la metrologie et occasionner des dommages 
   sur les paliers et les pistons en raison du melange du lubrifiant et des impuretes contenues dans 
   le gaz.
-  Toujours vidanger les carters avant le transport du compteur.
3.3.2 Choix du lubrifiant
Viscosite : la viscosite a ete calculee pour assurer la meilleure performance mecanique et 
metrologique du compteur.
References commerciales : L'annexe 3 contient une liste de lubrifiants du commerce. Ils peuvent 
etre utilises pour les gaz industriels, â l'exception des gaz tels qu'oxygene et halogenes. En cas 
d'utilisation avec d'autres gaz, veuillez nous consulter.
La viscosite des lubrifiants varie avec la temperature. L'annexe 4 contient des indications 
concernant la gamme de temperature compatible avec un lubrifiant de viscosite conformement â 
l'ISO 3 448 â 40 °C.
3.3.3 Contenance des carters : voir l'annexe 5. 
3.3. 4 Remplissage et vidange
Voir l'annexe 6 pour l'emplacement des bouchons de remplissage, de vidange et des voyants de 
niveau de lubrifiant.
Les niveaux de lubrifiant doivent etre effectues dans les carters avant et arriere sauf pour le DN40
File : DELTA_Instruction_manual_2008-01-21_T5E başvurusu i çin.doc 5eite 9 von 52