Microlife BP 3AS1-2 YARI OTOMATİK KOLDAN ÖLÇEN TANSİYON ALETİ Tansiyon Aleti
M_3AS1_2_E&TR_rev2.qxd 09.04.2007 15:55 Page 12 8. Guarantee 10. Technical specifications: The blood-pressure monitor BP 3AS1-2 is guaranteed for 2 years from date of purchase. This guarantee Weight: 300 g (with batteries and M size cuff) includes the instrument and the cuff. The guarantee does not apply to damage caused by improper handling, Size: 68 (W) x 186 (L) x 85 (H) mm accidents, not following the operating instructions or alterations made to the instrument by third parties. Storage temperature: –20 to +50°C The guarantee is only valid upon presentation of the guarantee card filled out by the dealer. Humidity: 15 to 90% relative humidity maximum Operation temperature: 10 to 40°C Name and company address of the responsible dealer: Display: LCD-Display (Liquid Crystal Display) Measuring method: oscillometric Responsible Dealer / Central Service: TRİMPEKS İth. İhr. Tur. ve Tic. A.Ş. / Eski Büyükdere cad. Yunus Pressure sensor: capacitive Emre sok. no:1/12 Topçu İş Merkezi 4. Levent 34418 İSTANBUL - Türkiye / e-posta: trimpeks@trimpeks.com, Measuring range: teknikservis@trimpeks.com / www.trimpeks.com / Tel: +90 212 319 50 00 / Faks: +90 212 319 50 50 SYS/DIA: 30 to 280 mmHg Black Sea Region Service: Nova Medikal San. İnş. Tah. ve Tic. Ltd. Şti. / Yeşiltepe mah. Ballıca sok. Tanjant Pulse: 40 to 200 per minute yolu no:27 TRABZON - Türkiye / Tel: +90 462 230 33 70 / Faks: +90 462 230 62 96 Cuff pressure display range: 0–299 mmHg Aegean Region Service: Elektro Teknik Medikal / 848 sok. 2. Beyler no:37/7 Kemeraltı İZMİR - Türkiye Memory: Storing the last measurements automatically Tel: +90 232 441 43 19 / Faks: +90 232 484 06 23 Measuring resolution: 1 mmHg Accuracy: Pressure within ± 3 mmHg Pulse ± 5 % of the reading 9. Reference to standards Power source: 2 dry cells (batteries) AM-4, size AAA, 1.5 V Device standard: Device corresponds to the requirements of the Accessories: cuff type M for arm circumference 22–32 cm European standard for non-invasive blood-pressure monitor Technical alterations reserved! EN1060–1 / 12:95 EN1060–3 / 09:97 11. www.microlife.com DIN 58130, NIBP – clinical investigation ANSI / AAMI SP10, NIBP- requirements Detailed user information about our thermometers and blood pressure monitors as well as services can be found at www.microlife.com. Electromagn. compatibility: Device fulfils the stipulations of the European standard EN 60601–1–2 Clinical testing: The clinical performance test was carried out in Germany according to the DIN 58130/1997 procedure N6 (sequential). The stipulations of the EU-Guidelines 93/42/EWG for Medical Products Class IIa have been fulfilled. 12 13