Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 1. sayfa 1 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 2. sayfa 2 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 3. sayfa 3 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 4. sayfa 4 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 5. sayfa 5 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 6. sayfa 6 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 7. sayfa 7 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 8. sayfa 8 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 9. sayfa 9 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 10. sayfa 10 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 11. sayfa 11 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 12. sayfa 12 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 13. sayfa 13 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 14. sayfa 14 Daikin Klima RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE 15. sayfa 15


Daikin RXG50K2V1B DUVAR TİPİ-DIŞ ÜNİTE Klima

ArÕza Giderme







   ■    DIŞ ÜNİTE PCB’DEKİ LED IŞIĞI 


        3MXS, 4MXS, 5MXS serisi


                YEŞİL                            KIRMIZI

           MİKROBİLGİSAYAR 
                NORMAL                      ARIZA TESPİTİ

                LED-A              LED1    LED2    LED3    LED4    LED5                                          TEŞHİS

                                      •       •      •       •       •     NORMAL         ÜNİTEYİ KONTROL ET

                                              •                      •     YÜKSEK BASINÇ KORUYUCUSU ÇALIŞTI VEYA ÇALIŞAN 
                                                                           ÜNİTEDE VEYA BEKLEME ÜNİTESİNDE DONMA VAR

                                              •              •       •     * AŞIRI YÜK RÖLESİ ÇALIŞTI VEYA YÜKSEK BOŞALMA BORUSU
                                                                             SICAKLIĞ`I

                                      •                      •       •     ARIZALI KOMPRESÖR BAŞLATMASI

                                      •              •               •     GİRİŞ AŞIRI AKIMI

                                                     •       •       •     * TERMİSTÖR VEYA CT ANORMALLİĞ`İ

                                                     •               •     YÜKSEK SICAKLIK ŞALTER KUTUSU

                                      •       •      •               •     İNVERTER DEVRESİ SOĞ`UTUCUSUNDA YÜKSEK SICAKLIK

                                      •       •              •       •     * ÇIKIŞ AŞIRI AKIMI

                                      •       •                      •     * SOĞ`UTUCU EKSİKLİĞ`İ

                                              •      •               •     ANA DEVREYE GİDEN DÜŞÜK VOLTAJ VEYA ANLIK VOLTAJ KAYBI

                                              •      •       •       •     TERSİNE SOLENOİD VALF GEÇİŞ ARIZASI

                                                                     •     FAN MOTORU ARIZASI

                                      —       —      —       —       •     [AÇIKLAMA 1]

                    •                 —       —      —       —       •     GÜÇ BESLEMESİ ARIZASI VEYA [AÇIKLAMA 2]

                                                           AÇIKLAMA: LED5 sadece 5M serisinde vardÕr.

           YEŞİL       NORMALDE YANIP SÖNER

         KIRMIZI       NORMALDE KAPALI

                       AÇIK

                       YANIP SÖNÜYOR

              •        KAPALI

              —        İLGİSİZ





   ■    DIŞ ÜNİTE PCB’DEKİ LED IŞIĞI 


        2MXS serisi


                       YEŞİL

        MİKROBİLGİSAYAR NORMAL

                       LED-A                                               TEŞHİS

                                                NORMAL         ÜNİTEYİ KONTROL ET

                                                [AÇIKLAMA 1]

                          •                     GÜÇ BESLEMESİ ARIZASI VEYA [AÇIKLAMA 2]


         YEŞİL      NORMALDE YANIP SÖNER

                    AÇIK

                    YANIP SÖNÜYOR

            •       KAPALI








   AÇIKLAMA

    • Gücü kapatÕp sonra tekrar açÕn. LED ekranÕ yeniden göründüğünde, dÕş ünite PCB’si arÕzalÕdÕr.
    • Teşhis işaretlendi
      * BazÕ durumlar için geçerli değildir. Detaylar için servis kÕlavuzuna bakÕn.





41