Ciat Fancoil MAJOR NCH 327SP 2TG 1. sayfa 1 Ciat Fancoil MAJOR NCH 327SP 2TG 2. sayfa 2 Ciat Fancoil MAJOR NCH 327SP 2TG 3. sayfa 3 Ciat Fancoil MAJOR NCH 327SP 2TG 4. sayfa 4 Ciat Fancoil MAJOR NCH 327SP 2TG 5. sayfa 5 Ciat Fancoil MAJOR NCH 327SP 2TG 6. sayfa 6 Ciat Fancoil MAJOR NCH 327SP 2TG 7. sayfa 7 Ciat Fancoil MAJOR NCH 327SP 2TG 8. sayfa 8 Ciat Fancoil MAJOR NCH 327SP 2TG 9. sayfa 9 Ciat Fancoil MAJOR NCH 327SP 2TG 10. sayfa 10 Ciat Fancoil MAJOR NCH 327SP 2TG 11. sayfa 11 Ciat Fancoil MAJOR NCH 327SP 2TG 12. sayfa 12 Ciat Fancoil MAJOR NCH 327SP 2TG 13. sayfa 13 Ciat Fancoil MAJOR NCH 327SP 2TG 14. sayfa 14 Ciat Fancoil MAJOR NCH 327SP 2TG 15. sayfa 15 Ciat Fancoil MAJOR NCH 327SP 2TG 16. sayfa 16 Ciat Fancoil MAJOR NCH 327SP 2TG 17. sayfa 17


Ciat MAJOR NCH 327SP 2TG Fancoil

MAJOR NCH 331 4TD

                 Duyarlı     Toplam      Toplam        Dp 
    Motor       Soğutma      Soğutma      Isıtma      Isıtma    Dp Soğutma     Lw 
   Referans     Kapasitesi  Kapasitesi  Kapasitesi 
                   Kw          kW          kW          kPa          kPa       dBA
      R1          3,70         4,74        4,6         16,7         6,3        64
      R2          3,47         4,45        4,51        15,8         5,9        58
      R3          2,94         3,84        4,05        12,1         4,9        57
      R4          2,55         3,36        3,69        9,5          4,1        51
      R5          2,18         2,91        3,34        7,3          3,5        44
      R6          1,84         2,5          3          5,5          2,9        41
      R7          1,47         2,01        2,55        3,7          2,2        34

MAJOR NCH     333 4TG

                 Duyarlı     Toplam      Toplam        Dp
    Motor       Soğutma      Soğutma      Isıtma      Isıtma    Dp Soğutma     Lw
   Referans     Kapasitesi  Kapasitesi  Kapasitesi
                   Kw          kW          kW          kPa          kPa       dBA

      R1          4,28         5,36        5,63        26,5         13,3       68
      R2            4          5,02        5,36        22,7         11,4       64
      R3          3,74         4,67        5,2         20,1         10,4       62
      R4           3,5         4,33        4,80        17,3         9,3        61
      R5          3,03         3,88        4,42        14,2         8,1        57
      R6          2,68         3,45        4,06        11,4          7         53
      R7          2,18         2,85        3,56        8,1          5,5        48

MAJOR NCH     333 4TD

                 Duyarlı     Toplam      Toplam        Dp
    Motor       Soğutma      Soğutma      Isıtma      Isıtma    Dp Soğutma     Lw
   Referans     Kapasitesi  Kapasitesi  Kapasitesi
                   Kw          kW          kW          kPa          kPa       dBA
      R1          4,21         5,31        5,63        23,5         11,3       67
      R2            4          5,02        5,27        21,7         10,4       65
      R3          3,72         4,68        5,1         20,1         10,4       64
      R4           3,4         4,31        4,79        17,3         9,3        60
      R5          3,04         3,85        4,42        14,2         8,1        55
      R6          2,67         3,42        4,06        11,4          7         53
      R7          2,18         2,83        3,56        8,2          5,5        45



ENERJİ TASARRUFU İÇİN YAPILMASI GEREKENLER:

   1. Cihazlar ortam ısısı algılayan termostadlarla kullanılmalıdır.Ortam 
       ısısına göre su sirkülasyonu sağlanacağı için elekrik tasarrufu 
       sağlanacaktır.

   2. Fan hız seviyesinin ortam şartlarına uygun ayarlanması.

   3. Cihazların hava emiş ve üfleme ağızlarının kapatılmaması.

   4. Cihazların hava filtresinin periyodik olarak temizlenmesi ve ömrünü 
       yitiren filtrenin yenisiyle değiştirilmesi