IMPORTANT SAFETY INSTRUCTIONS • Hold plug when rewinding onto cord reel. Do This vacuum cleaner is equipped with a plug and a
When using an electrical appliance, basic precaution not allow plug to whip when rewinding. cable, which rolls up automatically.
should always be followed, including the following: • Unplug before connecting the hose If anything gets damaged, both the plug and the
READ ALL INSTRUCTIONS • Do not pick up anything that is burning or cable must been repaired by a qualified repairman
BEFORE USING (THIS APPUANCE) smoking, such as cigarettes, matches, or hat ashes. or electrician.
• Do not use without dust bag and/or filter in place.
WARNINGTo reduce the risk of fire, electric shock 18.If the supply cord is damaged, it must be ASSEMBLING VACUUM CLEANER
or injury: replaced by the manufacturer or its service agent Always remove the plug from the power socket
• Do not leave vacuum cleaner when plugged in. or a similarly qualified person in order to avoid before fitting or removing accessories!
• Unplug from outlet when no use and before a hazard.
servicing. Connecting vacuum cleaner
• To reduce the risk of electric shock, do not use SAVE THESE INSTRUCTIONS 1. Fitting or removing the flexible hose
outdoors or on wet surfaces WARNING-to reduce the risk of electric shock, this
• Do not allow to be used as a toy. Close attention vacuum cleaner has a polarized plug (one blade is Fitting:
is necessary when used by near children. winderthan the other). This plug will fit in a polarized Insert flexible hose into the air intake duct
• Use only as described in this manual. Use only outlet only one way. If the plug does not fit full in on the top of appliance. Press until it clicks
manufactures recommend attachments. the outlet reverse the plug. If it stili does not fit, into position.
• Do not use with damaged cord or plug. If vacuum contract a qualified electrician to install the proper
cleaner is not working as it should, has been outlet do not change the plug in any way. Removing:
dropped, damaged, left outdoors, or dropped Removing the plug from the power socket. To release
into water, enter it to a service center. DUST COMPARTMENT SUBASSEMBLY SKETCH the flexible hose firmiy from the air intake dust.
• Do not pull or carry on cord, use cord as a handle, MAP PRECAUTIONARY MEASURES
ciose door on cord, or pull cord around sharp If the opening that sucks in the air, the suction pipe or 2.Fitting the extension tubes and accessories
edges or corners. Do not run vacuum cleaner over the telescopic wand stidc on pipe are blocked, you should
cord. Keep cord away from heated surfaces. switch off the vacuum deaner at once. First dear the a. Fitting the extension tube to the handle.
• Do not unplug by pulling on cord. To unplug, blodced substance before you attempt to start the vacuum
grasp the plug, not the cord. cleaner again.
• Do not handle plug or vacuum cleaner with wet
hands. • Do not operate the vacuum cleaner too ciose to
• Do not put any object into openings. Do not use heaters and Ilke radiators, cigarette butts etc.
with any opening blocked. Keep
free of dust, lint, hair and anything that may • Before you insert the plug into the wall contact, b. Fitting the extension tubes.
reduce airflow. make sure your hand is dry.
• Keep hair, loose clothing, fingers and all parts of
body away from openings and moving parts. • Before you start using the vacuum cleaner, please
• Turn all controls off before unplugging. remove large or sharp objects from the floor in
• Use extra care when cleaning on stairs. order to prevent that the paper filter is damaged.
• Do not use to pick up flammable or combustible
liquids, such as gasoline, or use in areas where • When you want to pull the plug from the wall
they may be present contact, please do this at the plug itseif and not
by means of the electrical cable. 8
• Always operate the cleaner with the dust 2. Changing filter for air-outlet
c. Fitting the brush to the extension tube. compartment subassembiy whole installed. a. Open the grille for air-outlet.
• The dust container must be emptied if the window b. When open the grille for air-outlet, the filter for
of the filter indicator turns fully red when the air-outlet is found.
cleaner is operating at maximum power and the c. Take the filter out and change a clean one.
nozzle is raised from the floor. d. Close the grille for air-outlet.
If you forget to attach HEPA and filter or attach its
in the wrong manner, the dust compartment
1. Cleaning and changing Biter and HEPA for
subassembiy may not rinse.
air-inlet
a. Rotate dustcup' clapboard until it is unlocked
d. Fitting Floor brush 1. After removing the flexible tube, handhold
b. Take out HEPA assembiy.
Ideal for the daily cleaning on carpets and hard handle and press the locking button.
floors. 2. Take out the dustcup.
3. Press the lock of dustcup's lower cover.
4. Carry away the dust-glass cap and Spill rubbish
5. Replace the dust compartment subassembiy until
c. Take out the bracket from the dustcup' clapboard
it is locked.
INSTRUC Cleaning and Changing filter or HEPA
Before using appliance, unwind a sufficient length • Filter for air-inlet should be cleaned at least twice
of cable and insert the plug into the power socket. a year or when it becomes visible solid.
A yellow mark on the power cable shows the ideal • Clean HEPA for air-let when you find it is filled d. Rotate HEPA from the dustcup' clapboard . until
it is unlocked.
cable length. Don't expend the cable beyond the red in.
mark. • HEPA for air-inlet and filter for air-outlet are
changed.
1.Press the ON/OFF button to switch the appliance • Always operate the cleaner with filters and HEPA
on. installed.
e. Rinse bracket and HEPA in lukewarm water an
2. To rewind the power cable, press the rewind • Otherwise, reduced suction or motor damage
button with one hand and guide the cable with may be result. dry Filter and HEPA completely. (HEPA is rinsec
by brush.)
the other hand to ensure that it does not whip • Disconnect from electrical outlet, before cleaning
causing damage. filter.
• Do not use a washing machine to rinse filter.
MAINTENANCE • Do not use hair drier to dry it.
1.5pilling rubbish from the dust compartment
subassembiy
f. Put the HEPA into the bracket or change new
HEPA, then put them back dustcup' clapboard
g. It should, however, be replaced every six months
to ensure peak performance of your vacuum.
9