Blue House Elektrikli Süpürge BH012B 1. sayfa 1 Blue House Elektrikli Süpürge BH012B 2. sayfa 2 Blue House Elektrikli Süpürge BH012B 3. sayfa 3 Blue House Elektrikli Süpürge BH012B 4. sayfa 4 Blue House Elektrikli Süpürge BH012B 5. sayfa 5 Blue House Elektrikli Süpürge BH012B 6. sayfa 6 Blue House Elektrikli Süpürge BH012B 7. sayfa 7


Blue House BH012B Elektrikli Süpürge

                                                                                • When the filter is dry, replace into theunit and                    IMPORTANT                                              • To separate the debris screen fromthe dust cup, 
                                                                                  replace the HEPA filter anddust cup container.                      Please Note:                                             hold the dust cup inone hand and turn the dust 
                                                                                • A severely soiled or clogged filter should be                       The "TapClean" HEPA Filter will stop most of the         cup cover counter clockwise and pull apart. 
                                                                                  thoroughly washed withfresh tepid water. A mild                     tiniest dust particles and airborne allergens from re-   To clean the debris screen, we recommend that 
                                                                                  detergentcan be used if required.                                   entering the air you breathe. In fact it stops 99.97%    you rinse it under lukewarm running water to 
                                                                                                                                                      of all particles as small as 0.3 microns - many times    remove the dirt that accumulates on it, but always 
                                                                                Changing & Cleaning the Post Motor Filter                             smaller than a human hair!!! Because of this             allow it to completely air dry before inserting 
                                                                                The post motor filter is a washable filter but should                 incredible filtration performance, the HEPA Filter       back into the vacuum.
                                                                                be replaced every three (3) months.                                   will quickly accumulate, Inside the white filter folds, 
                                                                                • Remove the filter cover from the frontof the unit                   many fine dust particles that are difficult to see but WARNING: Always remove the power plug from the 
                                                                                  and remove the filter.                                              which will eventually block or reduce your suction     wali outlet before assembling or removing 
                                                                                • Rinse the post motor filter in lukewarmwater and                    power - if not cleaned properly.                       accessories.
                                                                                  air dry the filter completelyfor 24 hours. Do not                   • To remove the dust cup container, first press on 
                                                                                  use a washingmachine to rinse the filter. Do                          the dust cup release button that is located on       EXTENDING THE TELESCOPIC TUBE
                                                                                  notuse a hair dryer to dry it. Air dry only.Never                     the dust cup handle and at the same time press       Push the plastic button and pull out the smaller 
                                                                                  operate the vacuum without thepost motor filter                       on the dust cup release button that is on the        tube.
                                                                                  in place.                                                             side of the upper housing. Then pull the dust cup 
                                                                                • When the filteris dry, replaceinto the filter                         container out.                                       INSERTING THE TELESCOPIC TUBE INTO THE MAIN 
                                                                                  coverand replace the filtercower to the unit.                       • To empty the dust cup container, press on the        UNIT
                                                                                • A severely soiled or clogged filter should be                         trap door release button that is on the back side    • Insert the telescopic tube into the holenext to 
                                                                                  thoroughly washed with fresh tepid water. A mild                      of the dust cup container.                             the dust cup handle. Make surethat the slot in 
                                                                                  detergent can be used if required.                                  • The HEPA filter is located underneath the              the handle fits correctly into the opening.
                                                                                                                                                        dust cup container. Remove the Non-Woven Pre-        • To remove the telescopic tube, pressthe telescopic 
                                                                                OPERATING INSTRUCTIONS                                                  Filter. Remove the HEPA filter, hold the edges         tube release button andpull the tube up.
                                                                                Emptying the Dust Cup Container and Cleaning /                          and pull it out slowly.
                                                                                Changing the Non-Woven Pre-Filter, HEPA Filter &                      • Hold the HEPA filter by the edges and vigorously     ATTACHING THE FLOOR BRUSH TO THE MAIN 
                                                                                Debris Screen                                                           "TapClean" the HEPA Filter dirty side down on a      UNIT
                                                                                                                                                        hard, flat surface until no more dust is observed    • Insert the floor brush into its location,in the 
                                                                                warning: Always unplug the unit from electrical                         falling out from between the pleats of the filter.     direction of the arrow.
                                                                                outlet before opening the Dust Cup (container).                         We recommend washing the HEPA filter once a          • To remove the floor brush from themain unit, 
                                                                                                                                                        month or when suction appears to be reduced.           press on the floor brushrelease button and pull 
                                                                                important Do NOT use the vacuum without the HEPA                        Let the HEPA filter air dry completely for 24 hours.   the floor brushout.
                                                                                filter in place.                                                      • Rinse the non-woven pre-filter and letair dry 
                                                                                                                                                        completely for 24 hours.                             ATTACHING THE HOSE TO THE MAIN UNIT
                                                                                warning: After each Use -Always remove Filter                         • Insert the non-woven pre-filter.                     • Hold the end of the hose.
                                                                                Assembly and the Dust Cup Cover with the Debris                       • Reinstall the HEPA filter in the vacuum.             • Insert the hose into the hoseconnector.
                                                                                Screen, then vigorously "TapClean" HEPA Enter and 
                                                                                clean Debris Screen and Non-Woven Pre-Filter until 
                                                                                no more dust can be removed.
                                                                                                                                                                                                                                                              16


















         OPERATING INSTRUCTIONS                               WARNING                                                                                           Important: In order to ensure that maximum air 
                                                              After extended use, the body of the vacuum cleaner                                                suction is maintained, empty the dust cup frequently 
         WINDING & UNWINDING THE POWER CORD                   may become hot. When using the unit with the                                                      and shake out the HEPA filter and clean the non- 
         This vacuum cleaner is equipped with a convenient    shoulder strap, the unit will touch the body of the                                               woven pre-filter and debris screen at the same time.
         cord storage feature. The power cord winds around    user. Therefore, make sure that the unit body is cool 
         the two cord holders at the back of the unit. The    before you use with the shoulder strap. if during 
         bottom one has a quick cord release feature. Turn    use, the vacuum gets too warm, allow it to cool 
         the cord hook to the left or the right to remove the before continuing to use.
         power cord.
                                                              Crevice Tool
         ON/OFF SWITCH                                        For radiators, crevices, corners, baseboards and 
         The On/Off switch has two different                  between cushions.
         positions.
         Push on the "I" side to turn the vacuum ON.          Dusting Brush
         Push on the "O" side to turn the vacuum OFF.         fhe dusting brush is used for the furniture, venetian 
                                                              blinds, books, lamp shades and shelves.
         USING THE UNIT AS AN UPRIGHT
         • Unwind the power cordand plug into theV outlet.    Intelli-SenseTM Filter Monitor
         • Push down on thelocking button to adjustthe        When the Intelli-SenseTM Filter Monitor lights up, 
           height of thetelescopic handle.                    it means that the dust cup is full or the HEPA filter, 
                                                              non-woven pre-filter or debris screen needs cleaning. 
         NOTE: When vacuuming deep pile carpets or hard       You must empty the dust from the dust cup and 
         to vacuum carpets lower the angle of the telescopic  clean the HEPA filter, non-woven pre-filter and 
         handle (see illustration at right) for easier        debris screen right away.
         maneuverability.

         USING THE UNIT AS A HAND VACUUM
         • Press the telescopic tube releasebutton to remove 
           the telescopic tube.
         • Press the floor brush release button toremove 
           the floor brush.
         • Attach the shoulder strap to theshoulder strap 
           attachment point.
         • Attach the crevice tool or the dustingbrush to the 
           end of the hose.





17