Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 1. sayfa 1 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 2. sayfa 2 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 3. sayfa 3 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 4. sayfa 4 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 5. sayfa 5 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 6. sayfa 6 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 7. sayfa 7 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 8. sayfa 8 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 9. sayfa 9 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 10. sayfa 10 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 11. sayfa 11 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 12. sayfa 12 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 13. sayfa 13 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 14. sayfa 14 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 15. sayfa 15 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 16. sayfa 16 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 17. sayfa 17 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 18. sayfa 18 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 19. sayfa 19 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 20. sayfa 20 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 21. sayfa 21 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 22. sayfa 22 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 23. sayfa 23 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 24. sayfa 24 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 25. sayfa 25 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 26. sayfa 26 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 27. sayfa 27 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 28. sayfa 28 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 29. sayfa 29 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 30. sayfa 30 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 31. sayfa 31 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 32. sayfa 32 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 33. sayfa 33 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 34. sayfa 34 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 35. sayfa 35 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 36. sayfa 36 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 37. sayfa 37 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 38. sayfa 38 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 39. sayfa 39 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 40. sayfa 40 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 41. sayfa 41 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 42. sayfa 42 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 43. sayfa 43 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 44. sayfa 44 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 45. sayfa 45 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 46. sayfa 46 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 47. sayfa 47 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 48. sayfa 48 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 49. sayfa 49 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 50. sayfa 50 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 51. sayfa 51 Actaris Doğalgaz Sayacı G 40 S1-FLOW  DÖNER PİSTONLU (ROTARY) 52. sayfa 52


Actaris G 40 S1-FLOW DÖNER PİSTONLU (ROTARY) Doğalgaz Sayacı

-  Du gaz peut rester dans le compteur ou la canalisation, c'est pourquoi une ventilation suffisante
   est necessaire.
5.3 Installation sans bi-pass : voir l'annexe 10
MISE EN SERVICE :
Proceder â la mise en service toutes vannes fermees.
-  Ouvrir lentement la vanne amont de façon â pressuriser le compteur. Les variations de pression
   ne doivent pas depasser 0.3 bars par seconde. Lorsque la pression est equilibree, ouvrir 
   entierement la vanne amont.
-  Ouvrir lentement la vanne aval. La vanne doit etre legerement ouverte pour maintenir :
          • la pression amont dans le compteur.
          • Un debit faible dans le compteur pendant la pressurisation (approx. 5% Qmax). 
Lorsque la pression aval est equilibree, la vanne aval peut etre entierement ouverte.
MISE HORS SERVICE :
-  Fermer la vanne aval tres lentement et verifier que le compteur n'enregistre plus de debit.
-  Fermer la vanne amont.
-  Ouvrir lentement le robinet V2. Les variations de pression ne doivent pas depasser 0.3 bars par
   seconde. S'assurer de la depressurisation complete du compteur.
-  Du gaz peut rester dans le compteur ou la canalisation, c'est pourquoi une ventilation suffisante
   est necessaire.
5. 4 Compteurs places apres un regulateur
L'installation doit etre effectuee conformement au manuel technique specifique du regulateur. Lors 
de la pressurisation ou de la depressurisation, il faut veiller â ce que les variations de pression ne 
depassent pas 0.3 bars par seconde.

6 Entretien 
6.1 Entretien du compteur
Une fois installe, le compteur ne necessite pas d"attention particuliere, hormis un suivi periodique
du lubrifiant contenu dans les carters.
Apres la mise en service :
Gaz naturel :apres quelques jours de service, le niveau du lubrifiant doit etre verifie.
Autres gaz :apres une periode de fonctionnement de 100 heures â compter de la mise en service,
le niveau de lubrifiant doit etre contrSle.
Si le niveau du lubrifiant est sensiblement bas, si le lubrifiant est emulsifie ou en cas de reaction
chimique entre le lubrifiant et le gaz, les caracteristiques du lubrifiant doivent etre changees.
Periode de remplacement du lubrifiant :
La periode entre les contrSles ou les remplacements du lubrifiant depend des conditions
d'exploitation (variations de pression, debit...).
Gaz naturel :dans des conditions d'utilisation normale, le lubrifiant doit etre remplace tous les 5 â 8
ans.
Autres gaz : veuillez nous consulter.
Utiliser un produit sans solvant ni alcool pour nettoyer le compteur.
En cas d'utilisation avec des gaz humides, les effets de la corrosion doivent etre periodiquement
verifies. En cas de corrosion importante, le compteur doit etre remplace.
Pieces detachees :
Les references des pieces detachees peuvent etre definies soit en fournissant le numero de serie â
Actaris, soit en utilisant le CD ROM de pieces detachees « Spare parts catalogue ».