Unimep ORION SERİSİ 1-2-4-6-8-10 TABANCALI ,1-2-3-4-5 ÜRÜNLÜ, LCD EKRANLI, LİTRE-PARA YAZAR , DALGIÇ/ EMİŞLİ POMPALI Akaryakıt Dağıtım Pompaları
Now enter the new price looking at display carefully. Press ‘Enter’ to confirm or press ‘CLR’ if
you made a mistake.Remove nozzle and control price section of display is showing the correct value
you have entered.
SPECIAL NOTICES :
• Please read this manual carefully and make a practice on your dispenser with your staff
related with operation of it.
• Do not hesitate to call us, if there is a point you do not understand.
• If there is an error or problem on your dispenser, call the service. First notice the error
code displayed on.
• Please do not attempt to repair or add a device to your dispenser without informing
service unit.
• Please do not install an electric device on or near your dispenser. If you need such a
device, apply to a qualified technician from your service.
• Please do not attempt to add or connect any device to electric connection box of
dispenser. Because the bottom section of dispenser is the most hazardous zone.
Therefore, all equipments located within this section must be explosion proof.
• We hope your dispenser will work for many years and satisfies your needing in the field
of fuel distribution.
POSSIBLE ERRORS AND CODES DISPLAYED ABOUT.
ERROR CODE MEANING What you do?
Power down or a fault on ac input like If the power is not really
E-00 voltage drop or interrupt interrupted call service
Place nozzle and finish this
Power line voltage drop for a short time delivery and start a new
E-01 while delivery is going on delivery. If this currently
occurs call service.
Your nozzle trigger is closed
Time out occurred in case of no delivery during estimated time or your
E-02 container is empty or a fault
and motor was running in by-pass mode.
on fuel piping or guiding
hydraulics.
Place nozzle. Try to power
down CPU by shutting down
E-03 No response from pulser(s) related fuse in the power
panel and turn on again with a
delay of 5 sec.If this problem
continued, call service.
Electromechanical totalizer can not be
E-04 Call service.
incremented.
Sensing element failure in pulser unit of
E-12 Call service.
currently delivering nozzle
E-21,22,23.... No response from pulser 1,2,3,4..if which Call service.
nozzle is active now.
This may occur in
Preset sale is finished but fuel is still submersible type dispensers
E-31,32,33.... if solenoid is kept open
flowing in a small quantity.
caused from a mechanical
problem.
Enter P-90 to unlock which
P.OFF Dispenser is locked electronically you will find the procedure in
this document .
If your dispenser never works nor shows an error code, this may be a fatal error on main power
or CPU unit may be out of order. Call service for changing CPU w ith a new one.