The set time value is read on the time indicator. value, the time starts to count. The displayed time
4-Combiner Rate: value decreases by one at the end of each minute.
The set combiner value is read on the combiner When the time is reset, the machine loads the set
rate indicator. The time mode button is pressed for value (as well as the temperature set value and
the other " t2 " and " t3 " modes. The operations combiner rate) entered for the " t2" mode and
no. 2, 3 and 4 are repeated for each time mode. 5 continues to work according to these new values.
seconds after the last pressed button, the machine Once the "t2" and "t3" modes are processed, the
gets off the adjustment position. machine emits a sound warning and stops
5-Fan Speed Adjustment: working. The time mode returns to "t1" in this
The fan speed adjustment is done after having case.
appeared all the adjusted values. The fan speed DRY COOKING:
adjustment is independent from the program. The Before giving the start, 100% convection (0%
speed adjustment should be done before each steam) rate is selected through the combiner
operation according to the type of the product to selection button. In this case only the heaters are
be cooked. engaged. The fan starts to function automatically.
6-Operation: The fan can not be stopped when the heaters are
The start button is pressed. The oven starts to engaged. However, the speed adjustment can be
function as per the adjusted values. changed. The time starts to count when the
7-Control During Operation: temperature reaches the adjusted (set) value. The
Once the oven starts, the set values can not be set time value decreases by one at the end of each
changed. However, these can be seen for control minute. If the oven door is opened when the time
purposes. The set time can be verified by pressing counts down, the machine emits a continuous
on the time set button. The set temperature can be warning sound and the time count is stopped. The
seen by pressing on the temperature set button. warning stops when the door is closed and the
3.2.3 - Operating Principles time continues to count from where it has
MANUAL START: remained. If it is desired to feed steam to the oven
After having entered the temperature, time and during the cooking operation, " Manual Steam
combiner rates, the oven starts to function by Button " is pressed. As long as it is kept pressed,
pressing on the start/stop button. In such a case, steam is fed into the oven. When the time is reset,
the time mode is not operative. The adjusted a sound warning is emitted, the heaters and fan are
values appear on the related indicators. After stopped and the stop position is taken. If it is
flashing for some time, it starts to show the actual desired to stop working before the end of time,
(measured on that point) values. Time starts to START/STOP button is pressed again.
count when the temperature reaches the adjusted STEAM COOKING (BOILING):
(set) value. The set time value decreases by one at Before giving the start, 0% convection (100%
the end of each minute. If the oven door is opened steam) rate is selected through the combiner
when the time counts down, the machine emits selection button. In this case the boiler is engaged
continuous warning signal and the time count and it starts to feed steam to the oven. The time
stops. When the door is closed, the warning stops starts to count when the set (adjusted) temperature
and time continues to count down from where it value is reached. The difference from the dry
has remained. When the time is reset, interrupted cooking is in that the boiler is engaged instead of
warning is emitted and the heaters and fan are the heaters. The fan can be stopped and operated
stopped and the stop position is taken. If it is when desired.
meant to stop working before the end of time, NOTE: In this case, do not enter a set value
START/STOP button is pressed again. above 850C.
PROGRAMMED START: COMBINER COOKING:
The program number, the temperature, time, time Before giving the start, DRY and STEAM
mode and combiner rates of which have been cooking operations are effected together at all
previously entered, is selected through the rates except the 100% convection or 100% steam
program increase and decrease button. The rates on the combiner selection indicator. In
adjusted values appear on the related indicators. periods of 1 minute, first the heater and then the
After flashing for some time, it starts to show the boiler is engaged according to the combiner rates.
actual (measured on that point) values. When the The fan can not be stopped when the heaters are
start/stop button is pressed, the temperature, time engaged, however, the fan can be manually started
and combiner rate entered for the "t1" is loaded and stopped when the boiler is engaged.
from the memory and the oven starts to function.
When the temperature reaches the adjusted (set)
14