What to do if problem Heart rate symbol Low battery indicator Measuring error Error Reason Appears in the measurement condition and flashes when pulse is detected. Appears when the battery voltage is excessively IoW or the positions of the batteries are incorrect. Appears When the accurate blood pressure and pulse could not be obtained. Solution • Measurement in progress, remain quiet • Replace all four batteries With new ones. Insert the batteries in the correct positions, Be aware Of +/- positions. • Press "Start/Stop" button again and remeasure. • Check if cuff is wrapped according to instructions. • Check that there are no kinks in tube. • Check palm if exerting effort. • Check if talking or moving during measurement. • Check if posture is correct. 0297 IMPORTANT Read the operating instructions. Classification: • Internally powered equipment • Type BF equipment • IPXO • Not suitable for use in the presence of flammable anæsthetic mixture with air, oxygen or nitrous oxide • Continuous operation with short-time loading Operating temperature Storage temperature This product conforms to the provisions of the EC directive 93/42/EEC (Medical Device Directive). This device conforms to the following standards: • EN 60601-1: 1990 + Al: 1993 + A2: 1995 A13: 1996 General requirements for safety. • EN 60601-1-2:2001 - Electromagnetic compatibility requirements and tests. • EN1060-1: 1995 + Al: 2002 - Non-invasive sphygmomanometers- General requirements . • EN1060-3: 1997 + Al: 2005 Non-invasive sphygmomanometers supplementary requirements for electromechanical blood pressure measuring systems. • EN10604: 2004 - Non-invasive sphygmomanometers- Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers. Specifications Method of measurement Model number Range of measurement Accuracy Inflation Exhaust Display Sets of memory Cuff size Operating temperature Storage temperature Unit weight Power supply Battery life Auto power off Accessories 8 Oscillometric BP4600 Pressure 0—300 mmHg Pulse 40—199 beats/minute Pressure +/- 3 mmHg Pulse +/- 5% max. Deluxe automatic Automatic exhaust valve Liquid crystal display — systolic, diastolic, pulse rate 32 sets • Small/Medium cuff = 23—33 cm arm circumference • Large/XLarge cuff = 33—43 cm arm circumference +10 'C - +40 •C, less than R.H. -20 -C - +60 •C, less than RH. 290g (without batteries) Alkaline battery: 4 x AA (LR6) 300 times measurement (twice a day measurement) Whenever not used for 1 minute 4 batteries, arm cuff with tube, instruction manual, pouch, carton box MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC. For detailed description Of EMC requirements please contact an authorized local Service Centre (see package insert). Portable and mobile RF communications equipment can affect medical electrical equipment. Please do not dispose of the product in the household waste at the end of its useful life. Disposal can take place at your local retailer or at appropriate collection points provided in your country. Guarantee See warranty statement inside the Kaz Customer Service Centre booklet. UK only: This guarantee in no way affects your rights under statutory law. 9