3 Technical and Configuration Limits
Number of CP 1613 modules in a PC
A maximum of 4 CP 1613 modules can be operated in a PG/PC at any one time.
Number of Applications at One Time
The number of appli cations that can be run at the same time depends on the
interfa ce used.
Interface Number of Applications/Connections
TF Interface • A maximum of 4 user programs at one time
• A maximum of 64 connections
Note
The connections must only be operated with a credit of 1.
SEND/RECEIVE • 10 SEND/RECEIVE user programs at the same time; in
interfa ce other words, up to 10 registrations ea ch with "SetSR( )"
are supported.
• 120 connections with PDU sizes up to 4096 bytes and a
credit of 1
Transport Protocol
TF communi cation is possible only over the ISO transport proto col.
Multiple Protocol Operation on Multiprocessor Systems
Has been approved.
Produktinformation/Produ ct Information Industrial Ethernet TF-1613/VNindows V6.0
S79220-A5819-X-01-7437 47