Kullanım Kılavuzları
S7–200 PLC Kullanma Kılavuzu ; ; GSD File for the EM 277 PROFIBUS-DP with a DPC31 ; MLFB : 6ES7 277-0AA2.-0XA0 ; ; DATE : 26-March-2001 ; Continuation of GSD File ;================================================ ;================================================ #Profibus_DP ; Module Definition List ;General parameters Module = ”2 Bytes Out/ 2 Bytes In -” 0x31 GSD_Revision = 1 EndModule Vendor_Name = ”Siemens” Module = ”8 Bytes Out/ 8 Bytes In -” 0x37 Model_Name = ”EM 277 PROFIBUS-DP” EndModule Revision = ”V1.02” Module = ”32 Bytes Out/ 32 Bytes In -” Ident_Number = 0x089D 0xC0,0x1F,0x1F Protocol_Ident = 0 EndModule Station_Type = 0 Module = ”64 Bytes Out/ 64 Bytes In -” FMS_supp = 0 0xC0,0x3F,0x3F Hardware_Release = ”1.00” EndModule Software_Release = ”1.02” Module = ”1 Word Out/ 1 Word In -” 0x70 9.6_supp = 1 EndModule 19.2_supp = 1 Module = ”2 Word Out/ 2 Word In -” 0x71 45.45_supp = 1 EndModule 93.75_supp = 1 Module = ”4 Word Out/ 4 Word In -” 0x73 187.5_supp = 1 EndModule 500_supp = 1 Module = ”8 Word Out/ 8 Word In -” 0x77 1.5M_supp = 1 EndModule 3M_supp = 1 Module = ”16 Word Out/ 16 Word In -” 0x7F 6M_supp = 1 EndModule 12M_supp = 1 Module = ”32 Word Out/ 32 Word In -” MaxTsdr_9.6 = 60 0xC0,0x5F,0x5F MaxTsdr_19.2 = 60 EndModule MaxTsdr_45.45 = 250 Module = ”2 Word Out/ 8 Word In -” MaxTsdr_93.75 = 60 0xC0,0x41,0x47 MaxTsdr_187.5 = 60 EndModule MaxTsdr_500 = 100 Module = ”4 Word Out/ 16 Word In -” MaxTsdr_1.5M = 150 0xC0,0x43,0x4F MaxTsdr_3M = 250 EndModule MaxTsdr_6M = 450 Module = ”8 Word Out/ 32 Word In -” MaxTsdr_12M = 800 0xC0,0x47,0x5F Redundancy = 0 EndModule Repeater_Ctrl_Sig = 2 Module = ”8 Word Out/ 2 Word In -” 24V_Pins = 2 0xC0,0x47,0x41 ; Slave-Specification: EndModule OrderNumber=”6ES7 277-0AA2.-0XA0” Module = ”16 Word Out/ 4 Word In -” Periphery=”SIMATIC S5” 0xC0,0x4F,0x43 Slave_Family=10@TdF@SIMATIC EndModule Freeze_Mode_supp = 1 Module = ”32 Word Out/ 8 Word In -” Sync_Mode_supp = 1 0xC0,0x5F,0x47 Set_Slave_Add_Supp = 0 EndModule Auto_Baud_supp = 1 Module = ”4 Byte buffer I/O -” 0xB3 Min_Slave_Intervall = 1 EndModule Fail_Safe = 0 Module = ”8 Byte buffer I/O -” 0xB7 Max_Diag_Data_Len = 6 EndModule Modul_Offset = 0 Module = ”12 Byte buffer I/O -” 0xBB Modular_Station = 1 EndModule Max_Module = 1 Module = ”16 Byte buffer I/O -” 0xBF Max_Input_len = 128 EndModule Max_Output_len = 128 Max_Data_len = 256 ; UserPrmData-Definition ExtUserPrmData=1 ”I/O Offset in the V-memory” Unsigned16 0 0-10239 EndExtUserPrmData ; UserPrmData: Length and Preset: User_Prm_Data_Len=3 User_Prm_Data= 0,0,0 Max_User_Prm_Data_Len=3 Ext_User_Prm_Data_Const(0)=0x00,0x00,0x00 Ext_User_Prm_Data_Ref(1)=1 Resim A–25 EM 277 PROFIBUS Modülü GSD Dosyasının Dökümü 382