Electrical connection
Voltage
Connected load
Protection class
Protective class
Maximum allowed net impedance
Mains fuse (slow-blow)
Water connection
Max. feed pressure
Max. feed temperature
Min. feed volume
Max. Suction height
performance data
Working pressure
Max. permissible pressure
Water flow rate
Max. flow rate
Detergent flow rate
Recoil force Of the trigger gun
Dimensions and weights
Length
Width
Height
Weight, ready to operate with acces-
sories
Technical specifications
kW
16 A
60 •c
23 N
463 mm
330 mm
667 mm
EN - 10
230 v
1-50 Hz
0,396 Q
+ jo,248 Q
12
10
19,3 kg
EC Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health requi-
rements Of the EU Directives, both in its basic design
and construction as well as in the version put into circu-
lation by us. This declaration shall cease to be valid if
the machine is modified without our prior approval.
Product:
Type:
High pressure cleaner
1.317-xxx
0.6 Mpa
l/min
15 Mpa
16 Mpa
l/min
l/min
l/min
5,7
m/s2
1,1 m/s2
80 dB(A)
dB(A)
3
96 dB(A)
Relevant EU Directives
2000/14,'EC
2004/108/EC
2006/42JEC (+2009/127/EC)
2011/65/EU
Applied harmonized standards
EN 50581
EN 55014-1: 2006+A1: 2009+A2: 2011
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 60335—1
EN 60335—2-79
EN 61000-3-2: 2014
EN 61000-3-11: 2000
EN 62233: 2008
Applied conformity evaluation method
2000/14/EC: Appendix V
Sound power level dB(A)
Measured:
Guaranteed:
93
96
The undersigned act on behalf and under the power Of
attorney of the company management.
. Jenner
CEO
S. Reiser
Head of Approbation
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
Sound pressure level L PA
Uncertainty
Sound power level LNA + Uncertainty
KWA
Subject to technical changes.
16
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212