Electrical connection
Voltage
Connected load
Protection class
Protective class
Mains fuse (slow-blow)
Water connection
Max. feed pressure
Max. feed temperature
Min. feed volume
Max. Suction height
Performance data
Working pressure
Max. permissible pressure
Water flow rate
Max. flow rate
Detergent flow rate
Recoil force of the trigger gun
Dimensions and weights
Length
Width
Height
Technical specifications
kW
40 •c
12,5 MPa
14,5 MPa
17 N
411 mm
305 mm
EN - 10
230 v
1-50 Hz
MPa
10
l/min
7,5
l/min
8,3
"min
l/min
584
mm
m/s2
m/s2
76 dB(A)
dB(A)
92 dB(A)
EC Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements Of the EU Directives, both in its basic design
and construction as well as in the version put into circu-
lation by us. This declaration shall cease to be valid if
the machine is modified without our prior approval.
Product:
Type:
High pressure cleaner
1.324-xxx
Relevant EU Directives
2000/14,'EC
2004/108/EC
2006/42JEC (+2009/127/EC)
2011/65/EU
Applied harmonized standards
EN 50581
EN 55014-1: 2006+A1: 2009+A2: 2011
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 60335—1
EN 60335—2-79
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
Applied conformity evaluation method
2000/14/EC: Appendix V
Sound power level dB(A)
Measured:
Guaranteed:
89
92
The undersigned act on behalf and under the power Of
attorney of the company management.
Weight, ready to operate with accesso- 14,0 kg
Values determined as per EN 60335-2-79
. Jenner
CEO
S. Reiser
Head of Approbation
Hand-arm vibration value
Uncertainty K
Sound pressure level L PA
Uncertainty KOA
Sound power level I-M + Uncertainty
KWA
Subject to technical changes.
16
3
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212