damages.
Pressure does not build up in the
appliance
Check setting at the spray lance.
Appliance ventilation.
Switch on the appliance without con-
nection the high-pressure hose (max. 2
minutes) and run it until the water dis-
charging from the high-pressure outlet
is free of bubbles. Switch off appliance
and reconnect high-pressure hose.
Check the water supply.
Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.
Appliance does not start, motor hums
Cause: Voltage reduction due to weak
mains supply or when using an extension
cable.
When switching on, first pull the lever of
the trigger gun and then switch the ap-
pliance switch to "I/ON".
Strong pressure fluctuations
Clean high-pressure nozzle: Remove
dirt and debris from the nozzle bore, us-
ing a needle and rinse through with wa-
ter from the front.
Check water flow quantity.
Appliance is leaking
Slight leakage from the appliance pump
is normal. If the leakage increases con-
tact the authorized customer service.
No detergent infeed
Use spray lance with pressure regula-
tion (Vario Power).
Turn the spray lance to "Mix" position.
Check the settings at the dosage regu-
lator for detergent.
Check the detergent suction hose for
kinks.
22
Appliance is not runnin
Pull on the lever of the trigger gun; the
device will switch on.
Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the mains supply.
Check the mains connection cable for
EN - 12
CE Declaration
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
Product:
High-pressure cleaner
Type:
1.168-xxx
Relevant EU Directives
2006/42/EC (+2009/127/EC)
2004/108/EC
2000/14/EC
Applied harmonized standards
EN 55014-1: 2006 + Al: 2009
EN 55014-2: 1997 + A2: 2008
EN 60335-1
EN 60335-2-79
EN 61000-3-2: 2006 + A2: 2009
EN 61000-3-3: 2008
EN 62233: 2008
Applied conformity evaluation rnethod
2000/14/EC: Appendix V
Sound power level dB(A)
Measured:
89
Guaranteed: 93
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
Jenner
CEO
S. Reiser
Head of Approbation
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2011/06/01