10
6. Compensating for
unevenness in the wall
6. Kompensaciä
nerovnostej steny
6. Duvar boşluklar∂n∂n
giderilmesi
7. Su bağlant∂s∂
7. Water connection
7. Podklühenie vody
15
90 120 mm
10
“hot”
”gorähaä voda“
“s∂cak”
“cold”
”xolodnaä voda“
“soğuk”
0 –25 mm
0 –25 mm
adjusting distance from wall
izmenäemoe rasstoänie do steny
Değişken duvar mesafesi
■
The water connection can be adjusted
vertically by slackening the locking screw
15.
■
Adapt the bend in the “hot” pipe so that
it lines up with the hot-water outlet. In so
doing, make sure that the “cold” elbow
connection is not bent.
Important!
Ensure that a distance of at least 6 mm is
maintained to live parts of the heater.
Connect the water outlet and inlet and
tighten the securing nut on the mounting
bolt.
■
S pomowæü ustanovohnogo vinta 15
qlement dlä podklüheniä vody moøno
otregulirovatæ po vysote na 10 mm.
■
Koleno truby ”gorähaä voda“ moøno
nemnogo izognutæ dlä sovmeweniä s
otverstiem dlä podahi gorähej vody. Pri
qtom ugolkovyj qlement podklüheniä
”xolodnaä voda“ izgibatæ nelæzä.
Vnimanie!
Sledite za tem, htoby rasstoänie meødu
tokoveduwimi qlementami i trubo-
provodami sostavlälo ne menee 6 mm.
Soedinite vse qlementy podklüheniä
i prohno zatänite krepeønuü gajku na
montaønom vinte.
■
15 numarali tesbit vidasi ile su bağlantisi,
±10 mm’ye kadar düµey olarak
ayarlanabilir.
■
“S∂cak” su borusunun dirseği su bağlan-
tisina uygundur. Bu esnada “Soğuk” su
bağlant∂s∂n∂n aç∂s∂ bükülmemelidir.
Dikkat!
Elektrik akim ileten kisimlara 6 mm’lik bir
mesafe bulunulmasina dikkat ediniz.
Su bağlanti vidalarini sikiniz ve montaj
vidasi tespit somununu sikiniz.